<link>http://www.primeconduit.com/faqs</link>	<item>
		<title><![CDATA[My customer is asking if the PVC conduit lasts ... (3697 views)]]></title>
		<description><![CDATA[[1.] My customer is asking if the PVC conduit lasts longer underground than the DB2.  Can you also give me the thickness on both of these?  (3697 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=7&amp;id=204&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 16 Apr 2008 14:22:00 GMT -->
		<pubDate>Sat, 04 Feb 2012 16:21:58 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[How would the EB-20 and EB-35 (Heavy Wall) and ... (2367 views)]]></title>
		<description><![CDATA[[2.] How would the EB-20 and EB-35 (Heavy Wall) and DB-60 and DB 120 (Heavy Wall) compare against the schedule 40 PVC conduits?  Are the number following the EB and DB, PVC schedule? (2367 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=7&amp;id=42&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 11 Apr 2008 13:33:00 GMT -->
		<pubDate>Sun, 05 Feb 2012 04:39:52 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[SDR vs. PVC Sch. 40 tensile strength - Can ... (2153 views)]]></title>
		<description><![CDATA[[3.] SDR vs. PVC Sch. 40 tensile strength - Can you direct me to that portion of your website were I could compare tensile strength of both. I want to guard against tearing HDPE with horizontal bore/reamer. (2153 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=4&amp;id=205&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 15:20:00 GMT -->
		<pubDate>Sat, 04 Feb 2012 00:27:39 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[I bought some 3" Bore-Guard and it has been ... (2096 views)]]></title>
		<description><![CDATA[[4.] I bought some 3" Bore-Guard and it has been sitting outside for 3 years.  The product is faded and they are concerned that it might not be able to stand the pressure of boring it.  (2096 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=4&amp;id=56&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 15:16:00 GMT -->
		<pubDate>Wed, 01 Feb 2012 18:24:47 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[Assuming a straight 10' length of schedule 80 conduit ... (1819 views)]]></title>
		<description><![CDATA[[5.] Assuming a straight 10' length of schedule 80 conduit how much flexure is acceptable or can safely be obtained without kinking the conduit? If one end is at zero and fixed how much bend can I put in the piece? How many inches off would the other end be?  (1819 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=9&amp;id=98&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 19:06:00 GMT -->
		<pubDate>Sat, 28 Jan 2012 09:50:31 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[Can Intra-gard be used for both power and communication ... (1753 views)]]></title>
		<description><![CDATA[[6.] Can Intra-gard be used for both power and communication conductors? (1753 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=5&amp;id=159&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Tue, 15 Apr 2008 20:59:00 GMT -->
		<pubDate>Wed, 25 Jan 2012 08:15:10 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[In and underground installation we are providing innerduct in ... (1709 views)]]></title>
		<description><![CDATA[[7.] In and underground installation we are providing innerduct in PVC conduit.  The question which has been raised, will (3) 1” innerducts fit into 4” schedule 80 PVC (3.826” ID)?  (1709 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=9&amp;id=144&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 19:07:00 GMT -->
		<pubDate>Sat, 04 Feb 2012 12:03:33 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[Is Bore-Gard ETL Listed? (1690 views)]]></title>
		<description><![CDATA[[8.] Is Bore-Gard ETL Listed? (1690 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=4&amp;id=4&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 15:14:00 GMT -->
		<pubDate>Fri, 27 Jan 2012 02:14:28 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[Do you still make Schedule 80 Bore-Gard PVC conduit? ... (1662 views)]]></title>
		<description><![CDATA[[9.] Do you still make Schedule 80 Bore-Gard PVC conduit? (1662 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=4&amp;id=57&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 15:19:00 GMT -->
		<pubDate>Sat, 21 Jan 2012 16:13:12 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[I have a contractor who would like to know ... (1648 views)]]></title>
		<description><![CDATA[[10.] I have a contractor who would like to know if primer must be used when connecting Sch40 PVC. In other words, will PVC cement work without the primer and is it considered to be installed correctly without the primer? (1648 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=9&amp;id=208&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 20 Jan 2012 19:14:00 GMT -->
		<pubDate>Fri, 03 Feb 2012 09:51:08 GMT</pubDate>
	</item>