<title>Prime Conduit FAQs - TOP 10</title>
<description>Prime Conduit Knowledgebase</description>
<link>http://www.primeconduit.com/faqs</link>	<item>
		<title><![CDATA[My customer is asking if the PVC conduit lasts ... (1741 views)]]></title>
		<description><![CDATA[[1.] My customer is asking if the PVC conduit lasts longer underground than the DB2.  Can you also give me the thickness on both of these?  (1741 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=7&amp;id=204&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 16 Apr 2008 14:22:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 12:42:51 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[How would the EB-20 and EB-35 (Heavy Wall) and ... (1070 views)]]></title>
		<description><![CDATA[[2.] How would the EB-20 and EB-35 (Heavy Wall) and DB-60 and DB 120 (Heavy Wall) compare against the schedule 40 PVC conduits?  Are the number following the EB and DB, PVC schedule? (1070 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=7&amp;id=42&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 11 Apr 2008 13:33:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 13:49:19 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[I have a request for quote for a part ... (934 views)]]></title>
		<description><![CDATA[[3.] I have a request for quote for a part number 68215. The material is called Loc Duct. Is it discontinued? (934 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=10&amp;id=157&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Tue, 15 Apr 2008 20:57:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 05:07:14 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[Assuming a straight 10' length of schedule 80 conduit ... (873 views)]]></title>
		<description><![CDATA[[4.] Assuming a straight 10' length of schedule 80 conduit how much flexure is acceptable or can safely be obtained without kinking the conduit? If one end is at zero and fixed how much bend can I put in the piece? How many inches off would the other end be?  (873 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=9&amp;id=98&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Fri, 11 Apr 2008 14:59:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 05:07:06 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[SDR vs. PVC Sch. 40 tensile strength - Can ... (854 views)]]></title>
		<description><![CDATA[[5.] SDR vs. PVC Sch. 40 tensile strength - Can you direct me to that portion of your website were I could compare tensile strength of both. I want to guard against tearing HDPE with horizontal bore/reamer. (854 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=4&amp;id=205&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 16 Apr 2008 14:22:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 05:01:49 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[I bought some 3" Bore-Guard in 2002 and it ... (815 views)]]></title>
		<description><![CDATA[[6.] I bought some 3" Bore-Guard in 2002 and it has been sitting outside ever since.  The product is faded and they are concerned that it might not be able to stand the pressure of boring it.  (815 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=4&amp;id=56&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 16 Apr 2008 14:25:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 14:57:05 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[What is the difference between type EB and DB ... (808 views)]]></title>
		<description><![CDATA[[7.] What is the difference between type EB and DB PVC?  What applications are each used for?  (808 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=7&amp;id=193&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 16 Apr 2008 14:11:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 09:17:33 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[I have a contractor who would like to know ... (768 views)]]></title>
		<description><![CDATA[[8.] I have a contractor who would like to know if primer must be used when connecting Sch40 PVC. In other words, will PVC cement work without the primer and is it considered to be installed correctly without the primer? (768 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=9&amp;id=208&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 22 Oct 2008 13:36:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 07:08:35 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[Can Intra-gard be used for both power and communication ... (757 views)]]></title>
		<description><![CDATA[[9.] Can Intra-gard be used for both power and communication conductors? (757 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=5&amp;id=159&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Tue, 15 Apr 2008 20:59:00 GMT -->
		<pubDate>Wed, 08 Sep 2010 12:18:31 GMT</pubDate>
	</item>
	<item>
		<title><![CDATA[What is the difference between NEMA standard TC-6 and ... (757 views)]]></title>
		<description><![CDATA[[10.] What is the difference between NEMA standard TC-6 and TC-8? (757 views)]]></description>
		<link>http://www.primeconduit.com/faqs/index.php?action=artikel&amp;cat=7&amp;id=190&amp;artlang=en</link>
		<!-- The real FAQ publication date -->
		<!-- Wed, 16 Apr 2008 13:54:00 GMT -->
		<pubDate>Tue, 07 Sep 2010 11:24:58 GMT</pubDate>
	</item>